Table of Contents Table of Contents
Previous Page  142 / 163 Next Page
Information
Show Menu
Previous Page 142 / 163 Next Page
Page Background

SL2000

P

VAC

LI

I N T E R N A T I O N A L P T Y L T D

Alignment Adjustment Instruction Sheet

A-Grub Screw Front/Back Control

B-Grub Screw Left/Right Control

C-Grub Screw Front/Back Control

D-Pulley Bolt

Problem:

Machine pulling right

Remedy:

Adjust B clockwise

Problem:

Machine pulling left

Remedy:

Adjust C counter-clockwise

Problem:

Machine dragging forward

Remedy:

Adjust A counter-clockwise

Problem:

Machine pushing backwards

Remedy:

Adjust A clockwise

N.B.

When adjusting grub screws use 1/2 turn increments.

When adjusting grub screws in a clockwise direction back off D by 1/4 - 1/2 turn,

adjust grub screw and re-tightened D.

Once grub screw is adjusted (and D is re-tightened where necessary) test machine

on floor for alignment and adjust further if required following the above procedure.

A

D

C

B