Product: ALL PURPOSE THINNERS
Page
4
of
7
ISSUE: 7 ISSUE DATE: 20/01/2015
Special protective equipment and precautions for fire fighters
Wear full protective clothing and self-contained breathing apparatus. Hazchem code ●3YE.
SECTION 6
ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Avoid contact with spilled or released material. Shut off leaks, if possible without personal risks. Isolate
hazard area and deny entry to unnecessary or unprotected personnel. Remove all sources of ignition in the
surrounding area. Take precautionary measure against static discharge. Ensure electrical continuity by
bonding and earthing all equipment.
Environmental precautions
Use appropriate containment to avoid environmental contamination. Prevent from spreading and entering
waterway using sand, earth or other appropriate barriers. Attempt to disperse the vapour or to direct its flow
to a safe location for example by using fog sprays. Ventilate contaminated area thoroughly.
Methods and materials for containment and cleaning up
For small spills (< 1 drum), transfer by mechanical means to a labelled, sealable container for product
recovery or safe disposal. Allow any residues to evaporate or use an appropriate absorbent material and
dispose of safely.
For larger spills (> 1 drum), transfer by means such as a vacuum truck to a salvage tank for recovery or
disposal. Do not flush residues with water. Retain as contaminated waste. Allow any residues to evaporate or
use an appropriate absorbent material and dispose of safely.
SECTION 7 HANDLING AND STORAGE
Precautions for safe handling
Highly flammable product. Avoid breathing vapours. Handle and open containers with care in a well-
ventilated area. Ensure that the workplace is ventilated such that the Occupational Exposure limit is not
exceeded. Avoid contact with skin, eyes and clothing. Wash thoroughly after handling. Do not eat, drink or
smoke in contaminated areas. Electrostatic charges may be generated during transfer. Electrostatic
discharge may cause fire. Ensure electrical continuity by earthing all equipment.
Conditions for safe storage, including any incompatibilities
Store in a well-ventilated area, away from sunlight, ignition sources and other sources of heat. Do not store
near strong oxidants.
SECTION 8
EXPOSURE CONTROLS AND PERSONAL PROTECTION
Exposure control measures
From National Occupational Health & Safety Commission (NOHSC) Worksafe Australia -
Toluene: 191mg/m³ (50ppm) TWA (8hr), 574mg/m³ (150ppm) STEL
Acetone: 1185mg/m³ (500ppm) TWA (8hr), 2375mg/m³ (1000ppm) STEL
Ethanol: 1880mg/m3 (1000ppm) TWA (8hr)
Biological monitoring
No biological limit allocated.
Engineering controls
Ensure that adequate ventilation is provided. Maintain air concentrations below recommended exposure
standards. Avoid generating and inhaling mists and vapours. Keep containers closed when not in use.
Individual protection measures
Eye and face protection:
Wear safety goggles.
Skin protection:
Use solvent resistant gloves, nitrile for longer term protection or PVC and
neoprene for incidental splashes.
Respiratory protection:
If work practices do not maintain airborne level below the exposure
standard, use appropriate respiratory protection equipment. When using
respirators, select an appropriate combination of mask and filter. Select a
filter for organic gases and vapours (boiling point > 65°C). Respirators